HCB-14 Circuit Breaker Analyzer

HCB-14 Circuit Breaker Analyzer

Brief Description:

HCB-14 Circuit Breaker Analyzer  is widely applicable to mechanical characteristics testing scenarios for various types of high-voltage switchgear, including vacuum switches, SF6 switches, and oil switches. It meets the testing needs of power system switchgear in various scenarios, including factory inspection, operation and maintenance testing, overhaul and commissioning, and scientific research testing, providing professional data support for the safe and stable operation of switchgear.


Product Detail

Product Tags

Features

• Equipped with a large, wide-temperature, direct-view backlit LCD display for displaying data and graphs; supports LCD contrast adjustment and features a power-off memory function.

• Captures complete mechanical characteristic test data and corresponding waveform graphs with a single switch operation.

• Supports selection and customization of opening and closing speeds, enabling arbitrary analysis and meeting the speed measurement requirements of various switch models.

• Supports measurement of inherent opening and closing times, as well as phase and interphase synchronicity for 12 circuit breakers.

• Captures time parameters for each circuit breaker during the close-open, open-close, and open-close-open operations, including first-open time, first-close time, second-close time, metal shorting time, and no-current time.

• Accurately measures closing bounce time, number of bounces, bounce process, and waveform for each circuit breaker, and simultaneously records opening rebound amplitude.

• Real-time acquisition of opening and closing speeds, maximum speeds, and generates time-travel characteristic curves. 8. Supports measurement of total travel, opening distance, over-travel, overshoot, and rebound amplitude.

•  Enables dynamic monitoring of opening and closing coil currents and generates current waveform.

• Integrated with a DC 0-300V/20A digitally adjustable circuit breaker operating power supply, it automatically completes low-voltage operating tests and accurately measures operating voltages.

• Flexible support for various sensor types, including acceleration, linear, and rotational sensors.

• Supports test data storage, with a built-in real-time clock that accurately records test dates and times for easy archiving and traceability.

• Supports stable connection to a PC via USB for convenient data exchange.

• Built-in printer quickly outputs data and graphs for immediate recording and storage. Test results can be printed on a variety of printers, offering strong compatibility and flexibility.

Specifications

Functions

Parameters

Time

Range

20000.0ms

Min. Resolution 0.01ms

Error

200 ms

0.01ms±0.1ms

2000 ms

0.1ms±0.1ms

20000 ms

1ms±0.1ms

Velocity

Range

20.00m/s

Min. Resolution 0.01m/s

Error

0~2m/s

±0.1m/s±1digital

≥2m/s

±0.2m/s±1digital

Travel

Vacuum breaker

50.0mm

  0.1mm, error 0.1±1digital

SF6 circuit breaker

300.0mm

1mm, error 0.1±1digital

Oil circuit breaker

600.0mm

1mm, error 0.1±1digital

Current

Max range

20.00A

resolution0.01A

Output power

 DC0-300V digital adjustable / 20A (instantaneous working), resolution 1V.

Insulation resistance

> 2MΩ

Dielectric strength

Shell can withstand power frequency voltage 1.5kV at    1 minute without flash-over and arcing

Temperature

-10--40℃

Humidity

≤80%RH

Air Pressure

 86-106kpa

Dimension

360mm* 280mm* 300mm

Weight

10kg

 